2011 Audi A3
Mileage
84,888
Service Date
12/10/2019
Services Performed
- CHECK SMOKE FROM EXHAUST
- PCV VALVE – Remove & Replace – In-Line4,Gas Crankcase Ventilation Regulating Valve
- RECOMMENDED FRONT REAR PRESSURE IN LF RF LR RR PRESSURE OUT LF RF LR RR
- Scanned DME and found codes as follows: P2015 INTAKE MANIFOLD FLAP POSITION SENSOR P0300 RANDOM CYLINDER MISFIRES P0301 MISFIRE CYL #1 P0303 MISFIRE CYL #3 P0304 MISFIRE CYL #4 P2015 INTERMITTENT CHECK ENGINE VACUUM-TOO HIGHT.VENT VALVE FAULTY.
Teri S. gave our service a 5 star review on 12/10/2019